CDXGT - BATTERY ELECTRIC STORAGE
- MSDS: CDXGT
- Manufacturer: EAST PENN MFG CO INC
- Product Name: BATTERY ELECTRIC STORAGE
- National Stock Number: 6140-00D006497
Product Identification
Product ID:BATTERY ELECTRIC STORAGE
MSDS Date:04/16/1990
FSC:6140
NIIN:00D006497
MSDS Number: CDXGT
Responsible Party
LYON STATION, PA 19536
US
Emergency Phone: 610-682-6361
Info Phone: 610-682-6361
Cage: 04055
Contractor
Telephone: 610-682-6361
Cage: 04055
Ingredients
LEAD (SARA 313) (CERCLA)
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: 43-70%
OSHA PEL SEE 1910.1025
ACGIH TLV: 0.05MG/M3, A3; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ANTIMONY (SARA 313) (CERCLA)
CAS: 7440-36-0
RTECS: CC4025000
Fraction By Weight: 0-4%
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.5 MG (SB)/M3; 9596
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
SULFURIC ACID (SARA 302/313) (CERCLA)
CAS: 7664-93-9
RTECS: WS5600000
Fraction By Weight: 20-44%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3/3 STEL; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SHORT TERM EXPO:SULFURIC ACID MAY
CAUSE IRRIT OF EYE/NOSE/THROAT.PROL CONTACT MAY CAUSE SEVERE
BURNS.LONG TERM EXPO:REP CONTACT CAUSES IRRIT & SKIN BURNS.REP EXPO
TO MIST MAY CAUSE EROSION OF TEETH,CH RONIC EYE IRRIT &/OR CHRONIC
INFLAMM OFNOSE/THROAT/BRONCHIAL TUBES.
Effects of Overexposure:ACID CONTACT MAY CAUSAE IRRIT OF
EYES/NOSE/THROAT.BREATHING OF MIST MAY PRODUCE RESPIRATORY
DIFFICULTY.CONTACT W/EYE/SKIN CAUSES IRRIT & SKIN BURNS.SULFURIC
ACID IS CORROSIVE CHEMICAL.
Medical Cond Aggravated by Exposure:PULMONARY EDEMA,
BRONCHITITS,EMPHYSEMAZ,DENTAL EROSION & TRACHEOBRONCHITIS. TARGET
ORGANS:RESPIRATORY SYSTEM,EYE,SKIN,TEETH.
First Aid
First Aid:FLUSH CONTACTED AREA W/LG AMTS OF WATER FOR @LEAST
15MINS.REMOVE CONTAMIN CLOTH & OBTAIN MED ATTN.IF SWALLOWED GIVE LG
VOLUMES OF WATER.DO NOT INDUCE VOMIT.OBTAIN MED TREATMENT.EYEWASH &
SHOWER STATIO NS SHOULD BE MADE AVAILABLE.
Fire Fighting
Flash Point:NON-FLAMM
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:0.4 HYDROGEN
Upper Limits:74 HYDROGEN
Extinguishing Media:CLASS ABC EXTINGUISHER, CO2 &/OR HALON.
Fire Fighting Procedures:COOL EXTERIOR OF BATTERY IF EXPOSED TO FIRE TO
PREVENT RUPTURE. THE ACID MIST/VAPOR IN FIRE SITUATION ARE
CORROSIVE.WEAR SPECIAL RESP PROTECTION(SCBA)& CLOTHING
Unusual Fire/Explosion Hazard:HYDROGEN GAS WHICH MAY EXPLO IF IGN IS
PRODUCED BY BATT ESPECIALLY WHEN CHARGING..USE ADEQUATE VENTI AVOID
OPEN FLAME/SPARK/OTHER SOURCES OF IGNITION.
Accidental Release
Spill Release Procedures:DILUTE SPILL CAUTIOUSLY W/FIVE TO SIX VOLUMES
OF WATER & GRADUALLY NEUTRALIZE W/SODIUM BICARBONATE, SODA ASH OR
LIME.WHEN EXPO LEVEL IS NOT KNOWN WEAR NIOSH APPROVED PRESSURE
SELF-COTNAINED RESPIRATOR .
Neutralizing Agent:SODIUM BICARBONATE, SODA ASH OR LIME.
Handling
Handling and Storage Precautions:STORE AWAY FROM REACTIVE MATL AS
DEFINED IN INCOPATIBILITY SECTION.
Other Precautions:SODIUM BICARBONATE,SODA ASH,SAND OR LIME SHOULD BE
KEPT IN SAME GENERAL AREA FOR EMERGENGY USE.
Exposure Controls
Respiratory Protection:ACID GAS RESPIRATOR REQUIRED WHEN PEL IS
EXCEEDED OR EMPLOYEE WITNESSES RESPIRATORY IRRIT.
Ventilation:WHEN PEL IS EXCEEDED LOCAL EXHAUST:PREFERRED.OTHER:ADEQUATE
VENTILATION TO MAINTAIN EXPO BELOW PEL.
Protective Gloves:ACID RESISTANT(RUBBER).
Eye Protection:CHEM SAFETY GOGG &/OR FACE SHIELD.
Other Protective Equipment:ACID-RESISTANT APRONS,BOOTS,PROTECTIVE
CLOTHING.
Work Hygienic Practices:GOOD PERSONAL HYGIENE & WORK PRACTICES ARE
MANDATORY.
Supplemental Safety and Health
Chemical Properties
HCC:C1
Boiling Pt:B.P. Text:235F,113C
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:NP
Vapor Pres:13
Vapor Density:NA
Spec Gravity:1.220-1.325
pH:NP
Viscosity:NP
Evaporation Rate & Reference:<1.0, BUTYL ACETATE=1
Solubility in Water:COMPLETELY
Appearance and Odor:CLEAR, ODORLESS, COLORLESS
Percent Volatiles by Volume:NP
Corrosion Rate:NP
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS SUCH AS HOT NITRIC ACID, ETC.
Stability Condition to Avoid:CASES DECOMPOSES @160-410C (322-770F).
Hazardous Decomposition Products:COMBUSTION CAN PRODUCE CARBON DIOXIDE
(CO2) & CARBON MONOXIDE (CO).
Disposal
Waste Disposal Methods:PLACE IN ACID-RESISTANT CNTNRS.DISPOSAL MUST BE
MADE IN ACCORDANCE WITH APPLICABLE GOVT REGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.